Elektromagnetic flow meters

FG4000 - electromagnetic flow meter



FG4000 - electromagnetic flow meter

The FG4000 magnetic flow meter is primarily designed for a wide range of industrial applications. Flow is determined on the electromagnetic induction principle that allows measuring it without any mechanical parts in the metering profile, which results in virtually no pressure drop.

The FG4000 flow meter is a highly reliably instrument that offers accurate flow measurement in liquids at long-term stability. This flow meter further features awide flow range while maintaining measurement accuracy with fast response to flow fluctuations. An alphanumeric display and three membrane keys provide comfortable operation. Last but not least, accent is put on design user-friendliness, such as easy access to the connectors.

The basic structure comprises a rigid aluminium casting that allows four positions of the flowtube in a horizontal or vertical pipe line while the correct operation position of the stainless steel front panel with display and membrane keys is always provided. The FG4000 flow meter advanced industrial design satisfies stringent requirements for mechanical as well as chemical resistance thus allowing to use the instrument under most rigorous conditions. The flow meter has ingression rating IP67 while its increased resistance against electromagnetic interference in compliance with category E2 pursuant to EN ISO 4064-5 may be stressed.

Principal Features:

  • wafer and flanged flowtubes
  • compact or split design
  • applicability in chemical and food industries as well as in potable water treatment (stainless steel flowtube)
  • Ucustomizable view of measurement values on display
  • operation setup (flow conversion coefficient, type of communication and its transmission rate, measuring dynamics, etc.) using membrane keys or application software
  • flowtube replaceability (each flowtube has its own calibration constants)
  • accessories – installation set (iron, stainless steel or made to customer specifications)
  • Visikal application software
  • bidirectional flow measurement (separate counter for each direction)
  • self-diagnostics – instrument status indicated on display
  • volumetric monitoring on up to 5 resettable flow rate totalizers (counters)
  • monitoring of maximum flow reached within a time interval
  • option to connect up to two external devices (flow meters) to pulse inputs and to display their flow rate and volume information
  • easy integration into other manufacturers’ host systems using pulse frequency modulation or analogue outputs
  • optional temperature measurement module
  • archiving of date time stamped measurement data for up to one year in non-volatile memory
  • uptime records
  • power failure and error condition records

FG4000 flow meter specifications:

  • Measuring range:
  • 1 :40 ( ±0,5% for MPE standard); 1:500 (Q0=0,2% Qmax)
  • Accuracy:
  • ± 0.5 % (± 0.003 m/s) in range from Qmin do Qmax
  • Minimum liquid conductivity:
  • >5ųS/cm – common liquids; ≥20ųS/cm – demineralized water
  • Power supplý:
  • 230 VAC (+10;−15%) 50–60Hz; optionally 120VAC, 24VAC, 24VDC
  • Power demand:
  • 10 VA
  • IEC 536 protection class:
  • I
  • Ingress protection rating:
  • IP67
  • Meter finish:
  • powder paint (RAL 8023)
  • Ambient temperature rangé:
  • 0–70°C; recommended 15–55°C
  • Pulse output 1:
  • in range 0.0001–1600 p/dm3 (maximum value depends on flowtube inner diameter)
  • Pulse output 2:
  • for negative volume and flow (with bidirectional flow)
  • Pulse inputs:
  • 2× range (0.0001–1000 p/dm3) to display flow and/or volume measured by external
  • Empty pipeline indication:
  • yes (optional)
  • Communication modules:
  • RS485, RS422, RS232, M-Bus, ... (optional)
  • Analogue outputs:
  • 4-20 mA, 0-10 V (optional)

    Flowtubes included:

  • Flowtube nominal inner diameter:
  • DN10 through DN600
  • Flowtube design:
  • flange, wafer, DIN 11851 threading, clamp, ...
    compact; split – 4m cabling (optionally up to 40m)
  • Flowtube liner:
  • hard rubber; PTFE; ECTFE
  • Electrodes:
  • 316L grade (1.4571) stainless steel; Hastelloy C; platinum; tantalum; titanium
  • Nominal pressure:
  • DIN, EN1092 - PN10, PN16, PN25, PN40; ANSI - 150lb, 300lb
  • Temperature range of liquid under:
  • 0-150 °C (PTFE); 0-90 °C (hard rubber)
  • Flowtube finish:
  • powder paint (RAL 7043); brushed stainless steel
  • Ingress protection rating:
  • IP67

    Dimensions of flow meter:

    (For dimensions of flow tubes see the concrete model)

    Compact design:

    FG 4000 – electromagnetic flow meter / compact design

    Split design:

    FG 4000 – electromagnetic flow meter / split design

    Table of included inner diameters:

    FG 4000


    Flanged flowtubes „F“
    Wafer flowtubes „W“
    Wafer flowtubes – stainless steel „W-ss“
    DN 10 15 20 25 32 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600
    Q0 (m3/h) 0,01 0,02 0,03 0,04 0,07 0,11 0,17 0,29 0,43 0,68 1,06 1,53 2,7 4,2 6,1 8,3 10,9 13,7 17,0 24,4
    Q1 (m3/h) 0,08 0,19 0,34 0,53 0,87 1,36 2,12 3,58 5,43 8,48 13,2 19,1 34,0 53,0 76,0 104 136 172 212 305
    Q3 (m3/h) 3,39 7,63 13,6 21,2 34,7 54,3 84,8 143 217 339 530 763 1360 2120 3050 4160 5431 6867 8480 12200
    k(Imp/dm3) 1600 700 400 200 150 100 60 35 25 15 10 7 4 2,5 1,6 1,25 1 0,75 0,5 0,4

    Legenda:

    DN - Flowtube nominal inner diameter
    Q0 - Starting flow
    Q1 - Minimal flow
    Q3 - Maximal flow
    k - Maximal constant of flow conversion